⚙ SRJPT STRIPS & PIPES — Mill Monitor

Refresh:
FM — RM — SMS — DC — HT —
Finishing Mill (FM)
Roughing Mill (RM)
Steel Melting (SMS)
Down Coiler (DC)
HT Power
AI Analysis
Loading…

Stand Speeds — Vact (m/s)

Stand Torque — Trqact (%)

Looper Angles (°)

AGC / Product Schedule
FM Stands
F1 – F9 Drive Data
StandVact (m/s)Nact (rpm)Vref ActTrqact (%)Uinact (V)Iaact (A)RunningCommOk
Loopers (L1–L8)
Looper Data
LooperAngle (°)Tens RefMactMtMwMtotal
Motor Temperatures (°C)
Mill Performance (%)
Loading…

R1 Speeds (m/s)

Rolling Force (T)

Pass Schedule
R1 Drive — Speeds & Currents
Main Drive
HGC — Hydraulic Gap Control
Gap / Stroke / Pressure
VE1 Edger
VE1 Drive & Hydraulics
Side Guides & Conveyors
DC Coiler
Pyrometers & Tracking
Motor Temperatures (°C)
Loading…
Furnace — Power & Status
MF FURNACE — POWER
KW—
KVA—
KVArH—
% Load—
Voltage (V)—
Current (A)—
PF—
Frequency—
Tapping Temp (°C)—
MW SELECTION
16 MW●
14 MW●
12 MW●
10 MW●
Upto 4.5 MW●
Deramp KW—
THYRISTOR / SEQ
8MW Thyristor●
12MW Thyristor●
14MW Thyristor●
Ramp/Deramp●
Seq NOT OK●
PLC Uptime—
FAULTS
Transformer●
Earth Leak 1●
Earth Leak 2●
Capacitor 1●
Capacitor 2●
Instrument●
Scanner 3●
Scanner 12●
Main EM●
EM1 / EM2● / ●
Energy Meters
ENERGY METER 1 (EM1)
V1 (V)—
V2 (V)—
V3 (V)—
I1 (A)—
I2 (A)—
I3 (A)—
KW—
KVA—
PF—
ENERGY METER 2 (EM2)
V1 (V)—
V2 (V)—
V3 (V)—
I1 (A)—
I2 (A)—
I3 (A)—
KW—
KVA—
PF—
Caster — Temperatures & Status
INDUCTION FURNACE WATER TEMPERATURES — GROUP A · Tag_75–98 (°C)
INDUCTION FURNACE WATER TEMPERATURES — GROUP B · Tag_147–170 (°C)
STRAND TEMPERATURES (°C) — Tag_728 / 730 / 732 / 734 · scale 1200–1800 °C · names not confirmed
Billet Strand 1 (Tag_728)
—
Billet Strand 2 (Tag_730)
—
Slab Strand 1 (Tag_732)
—
Slab Strand 2 (Tag_734)
—
Raw PLC integer scaled as 1200 + raw / 27648 × 600. The four tags barely move (about 20–30 °C in 12 days), so which strand each belongs to is unconfirmed until it is compared with the HMI while casting. A dash = outside 0–27648 (no signal).
CASTER 1 — DRIVE VALUES
CASTER 2 — DRIVE VALUES
Loading…
Live Tags — Down Coiler PLC (192.168.14.14)

Tags auto-discovered from DC PLC at 192.168.102.112:4840. Ensure portproxy rule is active on 192.168.102.112 machine.

Waiting for DC connection…
Last updated: —
Department V1 (kV) V2 (kV) V3 (kV) I1 (A) I2 (A) I3 (A) KW1 KW2 KW3 PF avg KVA KWH

🤖 Claude AI — Mill Process Analyser

Ask Claude to analyse current live data from both FM and RM PLCs.
It will check drive health, temperatures, AGC deviations, pass schedule, and more.

📊 Trend Snapshot

Analyse the last N rows of CSV history for trends and anomalies.